Comply with USP 797 & USP 800

Monitor temperature, RH and pressure in multiple rooms
Logs all sensor data automatically
Visual and audible alarm
Email or phone call alert
Easy touch display for setup
Max/Min updated every 4 seconds
Designed to support 21 CFR 11
Wired Ethernet socket
Color-coded display
100-hour internal backup battery
All logged data stored in non-volatile RAM
TV2 solution is a Low Cost Solution.
Cleanroom Monitor
USP Compliant
TV2 USP 797 and USP 800 cleanroom monitor
USP 797 Compliant
USP 800 Compliant
21 CFR 11 Compliant

Low Cost Does Not Mean Inaccurate

The TV2 QuickCheck monitor uses state-of-the-art differential pressure (±0.002"wg), temperature (±0.3°C) and humidity (±3.0%) sensors to check the environmental conditions every few seconds.

Each sensor comes with a NIST traceable calibration certificate. The TV2 sensors are highly engineered and designed to maintain their accuracy for many years. Each has excellent repeatability in addition to solid stability.

Each sensor has its own calibration table and analog to digital converter to ensure accuracy.

Buy Now
Certified Sensor Accuracy
01
Differential Pressure ±0.002"wg
02
Temperature ±0.3°C
03
Humidity ±3.0%
NIST Traceable Calibration Certificate

Quick to Install and Easy to Use

The TV2 Cleanroom monitor is the most affordable, easy-to-use negative/positive isolation room monitor available anywhere. Configuration of the monitor is done via a menu on the touch screen and takes just a few minutes.

The TV2 Cleanroom monitor alarms, logs and charts all three critical environmental variables needed to keep your pressurized areas safe and within specs 24/7. A glance at the QuickCheck digital display tells you immediately if everything is OK.

01
Touch-Screen Setup Configuration through an easy menu
02
Quick Installation Ready to use in just a few minutes
03
Three Variables Alarm, log and chart critical conditions
04
Instant Status Check system conditions at a glance
IV room cleanroom environmental monitoring
Environmental Monitoring

Monitor, Alarm, Log and Chart

The TV2 Cleanroom monitor is a temperature and humidity monitor and differential pressure monitor which also logs all three variables. If either temperature, humidity or pressure begins to drift outside of the “safe zone,” that condition turns red until the condition moves back into the safe zone.

The TV2 cleanroom monitor also logs each of the three environmental conditions—differential pressure, temperature and humidity.

Each variable is not only displayed so you know what the current conditions are, but the logged data for each variable can be viewed on the screen or downloaded to a PC and printed out as a line chart.

Local Safety Alert Audible & Visual Alarm

The TV2 IV Room Environmental monitor alarm triggers a local audible and visual indication and closes a N/O dry contact relay to trigger an auto-dialer or loud external local-alarm if present if your alarm setting as exceeded.

View the Logged Data on the Display or a PC

A continuous chart is always available. It can be seen on the TV2 IV room monitor itself or on any PC on the same network.

To see what happened last shift, just touch any of the environmental variables or download the data to a PC with the free TVView software. You can zoom out or in to view trends or highlight individual readings.

View Specifications
TV2 Display
On-Screen Data
TV2 logged data history display
Data Transfer
TVView Software
PC Data
TVView logged data chart on PC

Backing Up the Logged Data to a PC

Once the TV2 is part of a Local Area Network, all logged data can be automatically backed up to the computer. A chart can be viewed at any time. All logged data can also be exported into Excel.

!

Exporting the logged data into Excel, however, breaks the 21 CFR 11 requirements.

01
Connection Local Area Network
02
Automatic PC Data Backup
03
Optional Excel Export

IV Room Sensors

Each sensor used by the TV2 IV Room monitor has been manufactured for accuracy and reliability. Each sensor has a twenty-foot wire which plugs directly into the monitor, which can be extended to more than 200 feet to allow for remotely mounting the sensor from the monitor.

All data is transmitted digitally to the monitor to insure accuracy.

200+
Feet Extension Available for remote sensor mounting
TEMP Digital

Temperature Sensor

-20°C to 80°C ±0.3°C accuracy
RH Digital

Relative Humidity Sensor

0% to 100% ±3.0% accuracy
DP Digital

Differential Pressure Sensor

±0.500"wg ±0.002"wg accuracy

No Maintenance Fees or Labor

The TV2 monitor belongs to you and although the logged data can certainly be copied to any computer on the same network, or even your cloud, it does not cost you any extra to do so. The data is stored in the TV2 monitor itself and can be copied to files on any PC in your network. And all alarms are initiated by your monitor and not from your network.

Product Videos

Secure Your Cleanroom Today

Get a custom quote for your facility's monitoring requirements. Our technicians are ready to assist with sensor configuration, installation, and ongoing support.